General Description |
RATIONAL technology stands for outstanding quality and durability, maximum diversity of use and, above all, simple operational application. |
Capacity |
10 x 2/1 GN / 20 x 1/1 GN Lengthwise loading for: 2/1, 1/1 GN |
Number of meals per day |
150-300 |
Dimensions (mm) |
1069 (w) x 971 (d) x 1017 (h) Height incl. gas draft diverter: 1.256 mm Minimum distances (left, right, back): 50 mm Recommended distance for service work (left): 500 mm Minimum distance on left for heat sources: 350 mm |
Water supply (pressure hose) |
¾'' / Ø ½'' |
Water pressure (Flow pressure) |
150-600 kPa / 0,15-0,6 Mpa / 1,5-6 bar |
Minimum flow rate for filter and soft water system |
10,4 l/h |
Water drain |
DN 50 mm |
Electricity connection |
0,6 kW |
Weight (net) |
189,5 kg |
Fuse protection |
1 x 16 A |
Mains connection |
1 NAC 230 V |
Cable cross-section |
3 x 2,5 mm² (Supplied with 2.5 m cable / without connector) |
Gas supply/connection |
R¾" |
Connected flow pressure |
Natural gas H G20: 18 - 25 mbar Natural gas L G25: 20 - 30 mbar Liquefied gas G30: 25 - 57,5 mbar Liquefied gas G31: 25 - 57,5 mbar |
Exhaust gas duct |
A3 (nur Typ 61), B13, B23 |
Rated thermal load |
Liquid gas LPG total: 34 kW Liquid gas LPG "Moist heat": 34 kW Liquid gas LPG "Dry heat": 34 kW Natural gas total: 32 kW Natural gas "Moist heat": 32 kW Natural gas "Dry heat": 32 kW |
Marks of conformity |
CE, GS, KEMA, DVGW, SVGW, KIWA, IPX5, NSF, GASTEC QA, AGA/CSA, JIA, PCT |
Latent heat load |
6.667 kJ/h |
Sensitive heat load |
9.231 kJ/h |
Required air volume |
(unit free-standing in room): 1.267 m3/h (unit with one side against the wall): 798 m3/h (unit with two sides against the wall): 507 m3/h |