RATIONAL CM62G CombiMaster 62 Gas 6 Grid Combi

RATIONAL CM62G CombiMaster 62 Gas 6 Grid Combi - Image
MK Sales Price
Price available on application

Contact us for information

Product Specification (Code: CM62G)

General Description

RATIONAL technology stands for outstanding quality and durability, maximum diversity of use and, above all, simple operational application.

Dimensions (mm)

1069 (w) x 971 (d) x 757 (h)

Height incl. gas draft diverter: 996 mm

Minimum distances (left, right, back): 50 mm

Recommended distance for service work (left): 500 mm

Minimum distance on left for heat sources: 350 mm

Capacity

6 x 2/1 GN

Lengthwise loading for

2/1, 1/1 GN

Number of meals per day

60-160

Water supply (pressure hose)

'' / ''

Water pressure (Flow pressure)

150-600 kPa / 0,15-0,6 Mpa / 1,5-6 bar

Minimum flow rate for filter and soft water system

8,0 l/h

Water drain

DN 50 mm

Weight (net)

158,5 kg

Electricity connection

0,4 kW

Fuse protection

1 x 16 A

Mains connection

1 NAC 230 V

Cable cross-section

3 x 2,5 mm2 (Supplied with 2.5 m cable / without connector)

Gas supply/connection

R"

Connected flow pressure,

natural gas H G20: 18 - 25 mbar

natural gas L G25: 20 - 30 mbar

liquefied gas G30: 25 - 57,5 mbar

liquefied gas G31: 25 - 57,5 mbar

Exhaust gas duct

A3 (nur Typ 61), B13, B23

Rated thermal load

Liquid gas LPG total: 23 kW

Liquid gas LPG "Moist heat": 21 kW

Liquid gas LPG "Dry heat": 23 kW

Natural gas total: 21,5 kW

Natural gas "Moist heat": 20 kW

Natural gas "Dry heat": 21,5 kW

Marks of conformity

CE, GS, KEMA, DVGW, SVGW, KIWA, IPX5, NSF, GASTEC QA, AGA/CSA, JIA, PCT

Latent heat load

4.167 kJ/h

Sensitive heat load

5.000 kJ/h

Required air volume

(unit free-standing in room): 719 m3/h

(unit with one side against the wall): 453 m3/h

(unit with two sides against the wall): 288 m3/h