| General Description |
RATIONAL technology stands for outstanding quality and durability, maximum diversity of use and, above all, simple operational application. |
| Dimensions (mm) |
847 (w) x 771 (d) x 1017 (h) Minimum distances (left, right, back): 50 mm Recommended distance for service work (left): 500 mm Minimum distance on left for heat sources: 350 mm |
| Capacity |
10 x 1/1 GN |
| Lengthwise loading for |
1/1, 1/2, 2/3, 1/3, 2/8 GN |
| Number of meals per day |
80-150 |
| Water supply (pressure hose) |
¾'' / Ø ½'' |
| Water pressure (Flow pressure) |
150-600 kPa / 0,15-0,6 Mpa / 1,5-6 bar |
| Minimum flow rate for filter and soft water system |
6,3 l/h |
| Water drain |
DN 50 mm |
| Connected load |
19 kW |
| Fuse protection |
3 x 32 A |
| Mains connection |
3 NAC 400V |
| "Moist heat" connection |
18 kW |
| "Dry heat" connection |
18 kW |
| Weight (net) |
124,5 kg |
| Cable cross-section |
5 x 4 mm2 (Supplied with 2.5 m cable / without connector) |
| Marks of conformity |
CE, IPX5, VDE, UL, CUL, NSF, KEMA, PCT, GS, DVGW, SVGW, WRAS, KIWA |
| Latent heat load |
3.529 kJ/h |
| Sensitive heat load |
4.615 kJ/h |
| Required air volume |
(unit free-standing in room): 651 m3/h (unit with one side against the wall): 410 m3/h (unit with two sides against the wall): 260 m3/h |